{"id":3199,"date":"2024-07-16T13:45:14","date_gmt":"2024-07-16T09:45:14","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=3199"},"modified":"2024-12-18T14:18:34","modified_gmt":"2024-12-18T10:18:34","slug":"helium-leak-detector-lx218","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/helium-leak-detector-lx218\/","title":{"rendered":"Helium Leak Detector LX218"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">The essence of leak detection<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 54%\"><div class=\"wp-block-media-text__content\">\n<p class=\"has-medium-font-size\">The LINXON&nbsp;LX218 leak detector impresses with its powerful and reliable technology combined with low investment costs.&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"631\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/csm_device_49b2f2c5d2-1024x631.png\" alt=\"\" class=\"wp-image-3218 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/csm_device_49b2f2c5d2-1024x631.png 1024w, https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/csm_device_49b2f2c5d2-300x185.png 300w, https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/csm_device_49b2f2c5d2-768x473.png 768w, https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/csm_device_49b2f2c5d2.png 1357w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">LINXON LX218 &#8211; advantages at a glance<\/h2>\n\n\n\n<p>Integrated INFICON components enable first-class performance for absolute measurement accuracy at outstanding speed. The simple navigation and robust construction make the LX218 leak detector the ideal choice for companies in a wide range of industries. The helium leak detector has a start-up time of less than three minutes and offers a fast leak test and reaction time. A further advantage: With its vacuum mode and sniffing option, it is perfectly suited for efficient leak localization and leak size determination.<\/p>\n\n\n\n<ul>\n<li><strong>Competitive price<\/strong>&nbsp;thanks to standard components and direct distribution channels<\/li>\n\n\n\n<li><strong>Highest degree of availability and reliability<\/strong>, even after long periods of use, with proven vacuum technology components such as mass spectrometers, pumps and valves<\/li>\n\n\n\n<li><strong>Very short measuring times<\/strong>&nbsp;due to high pumping speed<\/li>\n\n\n\n<li><strong>Detection of the smallest leaks<\/strong>, even in environments contaminated by helium, with an intelligent stainless steel vacuum system<\/li>\n\n\n\n<li><strong>The highest quality<\/strong>&nbsp;in your production or service application guaranteed by high-precision INFICON measuring technology<\/li>\n\n\n\n<li><strong>Easy operation and installation<\/strong>, with no training required<\/li>\n\n\n\n<li><strong>Robust and versatile<\/strong>, it can be used even in the harshest production environments<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><em>Three LINXON Principles<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>PREMIUM QUALITY: Ensuring the highest quality by using proven technology.<\/li>\n\n\n\n<li>BEST PRICE: Low costs through the use of parts produced in large quantities and through lean distribution channels.<\/li>\n\n\n\n<li>EASY TO USE: LINXON devices are casy-to-use and robust.<\/li>\n<\/ul>\n\n\n\n<p><strong><em>At Eye Level with the Best<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>REAL 2.5 l\/s pumping speed in measure mode<\/li>\n\n\n\n<li>Detects leaks down to 1.10E-13 Pa.m3\/s<\/li>\n\n\n\n<li>Inlet pressure of 20<\/li>\n\n\n\n<li>Outstanding recovery after Cross leaks<br \/><em><br \/>You need nothing more for leak detection!<\/em><\/li>\n<\/ul>\n\n\n\n<p><strong><em>Easy &amp; Flexible Integration<\/em><\/strong><\/p>\n\n\n\n<p>Interfaces for data recording and transmission as well as process automation. &#8211; PLC &#8211; RS232 &#8211;<br \/>RS485<\/p>\n\n\n\n<p><strong><em>Solution: Intelligent Background Management<\/em><\/strong><\/p>\n\n\n\n<ul>\n<li>The LINXON LX218 is almost insensitive to high helium background due to the Cross leak protection mode &#8211; Whenever large quantities of helium occur, the LX218 switches off all valves within milliseconds.<\/li>\n\n\n\n<li>Intelligent design of the vacuum architecture prevents helium accumulation in the measuring system &#8211; Excellent electronic background suppression ZERO. Your Advantage: No background related downtime and no false rejects!<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">LINXON LX218 Downloads<\/h2>\n\n\n\n<p><a href=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/LX218_Brochure_EN-3.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">LINXON\u00ae LX218 Brochure<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/LX218-Operating-Manual-en1-08-2110.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">LINXON\u00ae LX218 Operation Manual<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LINXON LX218 Videos<\/h2>\n\n\n\n<p><a href=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/Unboxing-LX218.mp4\" target=\"_blank\" rel=\"noreferrer noopener\">LINXON\u00ae LX218 Unboxing<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2013\/11\/Installation-LX218.mp4\" target=\"_blank\" rel=\"noreferrer noopener\">LINXON\u00ae LX218 Installation Guide<\/a><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.linxon.net\/products\/lx218-helium-leak-detector\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3632\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Leak Detection Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The essence of leak detection The LINXON&nbsp;LX218 leak detector impresses with its powerful and reliable technology combined with low investment costs.&nbsp; LINXON LX218 &#8211; advantages at a glance Integrated INFICON components enable first-class performance for absolute measurement accuracy at outstanding speed. The simple navigation and robust construction make the LX218 leak detector the ideal choice [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":3218,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3199"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=3199"}],"version-history":[{"count":9,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3199\/revisions"}],"predecessor-version":[{"id":3975,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3199\/revisions\/3975"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media\/3218"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=3199"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}