{"id":3674,"date":"2024-12-18T15:22:24","date_gmt":"2024-12-18T11:22:24","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=3674"},"modified":"2024-12-18T15:22:24","modified_gmt":"2024-12-18T11:22:24","slug":"ul6000-fab-series","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/ul6000-fab-series\/","title":{"rendered":"UL6000 Fab Series"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\"><strong>UL6000 Fab \/ UL6000 Fab PLUS Leak Detectors<\/strong><\/h2>\n\n\n\n<p class=\"has-medium-font-size\">ULTRATEST\u2122 sensor technology&nbsp;<br \/>Sets new standards for speed and precision in leak testing.<\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 80%\"><div class=\"wp-block-media-text__content\">\n<p style=\"font-size:25px\"><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-164.png\" alt=\"\" class=\"wp-image-3675 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-164.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-164-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Helium Leak Detector Series for Semiconductor Applications<\/h2>\n\n\n\n<p>The INFICON UL6000 Fab&nbsp;Product Series&nbsp;is designed to meet the most critical and demanding leak detection applications. Featuring INFICON proprietary software algorithms I\u00b7CAL and HYDRO\u00b7S in a field-proven vacuum design, the UL6000 provides testing flexibility, high sensitivity and quick accurate results making any leak detection application fast and easy.<\/p>\n\n\n\n<p>The UL6000 delivers fastest response times in all measurement ranges and extremely short cycle times in reaching test conditions and final results. The specially designed vacuum architecture provides the continuous high helium pumping speeds and the extremely fast response times you demand.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Efficient leak testing<\/h2>\n\n\n\n<p>Leak detection is both time-consuming and complex. By measuring rate-of-rise, semiconductor- and vacuum equipment is continuously monitored during operation. Upon leak indication by this integral leak test, leak positions are then localized using the helium spraying method allowing for the required repair. This is followed by another leak test using pressure increase or so-called vacuum decay measurement \u2013 an intricate process which needs to be repeated until all leaks are detected. Moreover, to be as precise as possible, measurement times for this procedure are often particularly long for large equipment volumes. Thanks to I\u00b7RISE, our Intelligent Rate-of-rise feature, the UL6000 Fab PLUS performs pressure increase measurement all by itself and combines it with the helium spraying method. Our patented system enables measurement times to drop drastically, and thus helps minimize both general time for leak testing and fab equipment maintenance. Experience even faster and more precise measurement results \u2013 in under 10 seconds, independent of chamber volume.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Optimized Leak Testing with SMART-Spray, I\u00b7BOOST and SPRAY-Check<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/iss-lab.com\/?page_id=3667\" target=\"_blank\" rel=\"noreferrer noopener\">SMART-Spray<\/a><\/strong>\u00a0helium spray gun enhances leak checking by eliminating the need for large helium cylinders and cumbersome hoses. It streamlines the process, reducing manual helium flow adjustments and minimizing errors. This tool makes leak detection faster, easier, and more reliable while maintaining low helium consumption and background levels. Ideal for efficient and precise leak testing.<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/en\/smart-essentials\" target=\"_blank\" rel=\"noreferrer noopener\">I\u00b7BOOST<\/a><\/strong>\u00a0offers up to 50% time savings in leak detection. With shorter response times, it delivers fast and precise measurements across various chamber volumes, enhancing efficiency and accuracy. Additionally ,\u00a0<strong><a href=\"https:\/\/www.inficon.com\/en\/smart-essentials\" target=\"_blank\" rel=\"noreferrer noopener\">SPRAY-Check<\/a><\/strong>, a spray on test leak, ensures the functionality and readiness of your leak detector. Ideal for the 10\u207b\u2079 to 10\u207b\u2078 mbar\u2219l\/s range, it provides reliable checks during testing processes.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><br \/>Fab Product Series&nbsp;<\/strong><\/h2>\n\n\n\n<ul>\n<li>ULTRATEST Sensor Technology<\/li>\n\n\n\n<li>HYDRO-S (HYDROgen-Suppression) to enable test conditions to be reached quickly.<\/li>\n\n\n\n<li>I-CAL (Intelligent &#8211; Calculation Algorithm for Leak Rates) to ensure fast response to leaks in all measurement ranges.<\/li>\n\n\n\n<li>A special multiple inlet turbomolecular pump that provides optimized high helium pumping speeds with high helium compression at all pressures to deliver excellent sensitivity, response, and fast clean-up.<\/li>\n\n\n\n<li>A booster turbomolecular pump for extremely fast response on any test object, including the largest volumes and chambers.<\/li>\n\n\n\n<li>The field-proven INFICON magnetic sector mass spectrometer for years of accurate and repeatable results in a trouble-free, maintenance-free design.<\/li>\n\n\n\n<li>Self-protection features to protect the UL6000 from helium and particulate contamination and even an auto-purge cycle to ensure the UL6000 is ready when you need it.<\/li>\n\n\n\n<li>A rotatable display \/ control interface and optional remote hand controller for operational flexibility.<\/li>\n\n\n\n<li>Access control to the unit and system software can be enabled via the software to prevent unauthorized use or unintended modifications to test set-ups.<\/li>\n\n\n\n<li>Software updates via e-mail to keep your UL6000 at optimum performance.<\/li>\n\n\n\n<li>Work Station Design with an optimal height work surface that includes an ESD mat and tool box for testing convenience.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Fab PLUS Product Series<\/strong><\/h2>\n\n\n\n<ul>\n<li>Featuring I\u00b7RISE, our intelligent rate-of-rise: Provides in-device pressure increase testing combined with helium spraying method<\/li>\n\n\n\n<li>Rate-of-rise measurements in under 10 seconds<\/li>\n\n\n\n<li>Helps minimize general time for leak testing and fab equipment maintenance<\/li>\n\n\n\n<li>More speed, more precision<\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications<\/h2>\n\n\n\n<ul>\n<li>Leak testing of components, subassemblies and large chambers used on semiconductor and flat panel display tools<\/li>\n\n\n\n<li>Leak testing of semiconductor and flat panel tools<\/li>\n\n\n\n<li>Leak testing of aerospace components, subassemblies, and systems<\/li>\n\n\n\n<li>Leak testing of storage vessels\/storage tanks<\/li>\n\n\n\n<li><\/li>\n<\/ul>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<a href=\"https:\/\/www.inficon.com\/media\/5317\/download\/Brochure-UL6000-Fab-Product-Series.pdf?v=7&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\"><\/a><\/h2>\n\n\n\n<p><a href=\"https:\/\/www.inficon.com\/media\/5317\/download\/Brochure-UL6000-Fab-Product-Series.pdf?v=7&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Brochure UL6000 Fab Product Series<\/strong><\/a><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/leak-detectors\/ul6000-fab\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3632\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Leak Detection Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>UL6000 Fab \/ UL6000 Fab PLUS Leak Detectors ULTRATEST\u2122 sensor technology&nbsp;Sets new standards for speed and precision in leak testing. Helium Leak Detector Series for Semiconductor Applications The INFICON UL6000 Fab&nbsp;Product Series&nbsp;is designed to meet the most critical and demanding leak detection applications. Featuring INFICON proprietary software algorithms I\u00b7CAL and HYDRO\u00b7S in a field-proven vacuum [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3674"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=3674"}],"version-history":[{"count":5,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3674\/revisions"}],"predecessor-version":[{"id":3914,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3674\/revisions\/3914"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=3674"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}