{"id":3718,"date":"2024-12-18T15:26:21","date_gmt":"2024-12-18T11:26:21","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=3718"},"modified":"2024-12-18T15:26:21","modified_gmt":"2024-12-18T11:26:21","slug":"extrima","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/extrima\/","title":{"rendered":"Extrima\u00ae"},"content":{"rendered":"\n<p class=\"has-medium-font-size\">Ex-Certified Hydrogen Leak Detector<\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 82%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-172.png\" alt=\"\" class=\"wp-image-3719 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-172.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-172-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>The portable Extrima Leak Detector is the ultimate intrinsically safe instrument for leak detection in the toughest environments, including hazardous locations such as Zone 0 (corresponding to Division 1).<br \/><br \/>The Extrima allows you to quickly find leaks on a wide range of industrial applications such as aircraft and hydrogen cooled generators. With the Extrima the aviation industry has a safe, accurate and yet simple solution for leak testing of complete fuel systems, both in production and maintenance situations. Thanks to its high sensitivity, the Extrima can detect even minute leaks with pinpoint accuracy. Extensive tests have shown that using the Extrima can reduce the average time by more than 50 % for identifying, locating and repairing a leak on a fighter jet during maintenance.<\/p>\n\n\n\n<p>It is certified for use in Zone 0, classification Ex ia, IIC T3 with ATEX, IECEx, TIIS, NEPSI and CSA certificates. The Extrima can be used to trace leaks using Forming gas (5% H<sub>2<\/sub>\/95% N<sub>2<\/sub>) or in applications where pure hydrogen is used.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul>\n<li>Intrinsically safe: Ex ia IIC T3<\/li>\n\n\n\n<li>High sensitivity 0.5 ppm\/ 5E10<sup>-7<\/sup>cc\/s using 5% H<sub>2<\/sub>\/95% N<sub>2<\/sub><\/li>\n\n\n\n<li>Waterproof: IP 67<\/li>\n\n\n\n<li>1 minute start up time<\/li>\n\n\n\n<li>Unique selectivity to hydrogen<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Intrinsically safe for use in hazardous areas (Ex ia IIC T3)<\/li>\n\n\n\n<li>Robust enclosure for demanding field use<\/li>\n\n\n\n<li>High sensitivity and fast recovery allow for efficient operation<\/li>\n\n\n\n<li>Low and easy maintenance<\/li>\n\n\n\n<li>Portable, battery operated (more than 7 hours of use per charge)<\/li>\n\n\n\n<li>Sensor change in less than a minute<\/li>\n\n\n\n<li>Incorporates the proven Sensistor technology developed for using forming gas (5% hydrogen in nitrogen) as tracer gas<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications<\/h2>\n\n\n\n<ul>\n<li>Aerospace \u2013 complete fuel systems, oxygen supply, cooling systems and fire extinguishing systems, both in production and maintenance<\/li>\n\n\n\n<li>Power production \u2013 hydrogen-cooled generators and fuel cells<\/li>\n\n\n\n<li>Process industry \u2013 e.g., pipe systems, valves and containers<\/li>\n\n\n\n<li>Petro chemical industry<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Extrima Hydrogen Leak Detector | Aircraft Fuel Tank\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/dduGgmsJLcI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<p><\/p>\n\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5300\/download\/Extrima.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Extrima\u00ae Ex certified Hydrogen Leak Detector<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5381\/download\/Quality-Assurance-in-Utilities.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Quality Assurance in Utilities<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3671\/download\/Leak-Detection-in-Aviation.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Leak Detection in Aviation<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5326\/download\/Calibration-Leaks.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Calibration Leaks<\/a><\/strong><\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/leak-detectors\/extrima\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3632\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Leak Detection Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Ex-Certified Hydrogen Leak Detector The portable Extrima Leak Detector is the ultimate intrinsically safe instrument for leak detection in the toughest environments, including hazardous locations such as Zone 0 (corresponding to Division 1). The Extrima allows you to quickly find leaks on a wide range of industrial applications such as aircraft and hydrogen cooled generators. [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3718"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=3718"}],"version-history":[{"count":4,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3718\/revisions"}],"predecessor-version":[{"id":3935,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/3718\/revisions\/3935"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=3718"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}