{"id":4109,"date":"2024-12-19T14:35:51","date_gmt":"2024-12-19T10:35:51","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4109"},"modified":"2024-12-22T15:36:25","modified_gmt":"2024-12-22T11:36:25","slug":"pilot-plus-vacuum-gauge","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/pilot-plus-vacuum-gauge\/","title":{"rendered":"Pilot\u00ae Plus Vacuum Gauge"},"content":{"rendered":"\n<p>Superior Accuracy, Filter-Protected Sensor, and Extended Battery Life Provide More Jobsite Productivity.<\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 47%\"><div class=\"wp-block-media-text__content\">\n<p>INFICON Pilot Plus Vacuum Gauge incorporates several innovative features for unsurpassed performance. Like the original Pilot Vacuum Gauge, its Pirani sensor provides greater accuracy and the ability to measure the entire vacuum process, from atmosphere down to one micron. You&#8217;ll know instantly if your connections are vacuum-tight.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-231.png\" alt=\"\" class=\"wp-image-4110 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-231.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-231-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul>\n<li>Operates for 45 hours on one 9V battery<\/li>\n\n\n\n<li>Quick calibration specific to local pressure<\/li>\n\n\n\n<li>Displays in micron, Pascal, Torr or millibar<\/li>\n\n\n\n<li>Low battery indicator<\/li>\n\n\n\n<li>Plastic storage case included<\/li>\n\n\n\n<li>1-year replacement warranty<\/li>\n\n\n\n<li>Made in the USA<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"INFICON Pilot Plus Quick Start Video\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/mbj47V5C1Gk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Innovative filter protects sensor, eliminates need for cleaning<\/li>\n\n\n\n<li>Measures from atmosphere to 1 micron<\/li>\n\n\n\n<li>Auto shut-off after 60 minutes to conserve battery<\/li>\n\n\n\n<li>Pirani sensor for better accuracy<\/li>\n\n\n\n<li>Large, easy-to-read LCD display<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical Applications<\/h2>\n\n\n\n<ul>\n<li>Vacuum measurement in HVAC\/R service<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3579\/download\/Pilot-Plus-Product-Sheet-(English).pdf?v=5&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Pilot\u00ae Plus VACUUM GAUGE<\/a><\/strong><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3717\/download\/HVAC-R-Catalog---USA.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Tools for HVAC\/R Service<\/a><\/strong><\/p>\n\n\n\n<p><a href=\"https:\/\/www.inficon.com\/media\/5319\/download\/Leak-Testing-in-the-Automotive-Industry.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Leak Testing in the Automotive Industry<\/strong><\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/www.inficon.com\/media\/3674\/download\/RAC-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Leak testing in the HVACR Industry<\/strong><\/a><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/recovery-and-evacuation\/pilot-plus\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3632\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Leak Detection Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Superior Accuracy, Filter-Protected Sensor, and Extended Battery Life Provide More Jobsite Productivity. INFICON Pilot Plus Vacuum Gauge incorporates several innovative features for unsurpassed performance. Like the original Pilot Vacuum Gauge, its Pirani sensor provides greater accuracy and the ability to measure the entire vacuum process, from atmosphere down to one micron. You&#8217;ll know instantly if [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4109"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4109"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4109\/revisions"}],"predecessor-version":[{"id":4112,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4109\/revisions\/4112"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4109"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}