{"id":4154,"date":"2024-12-22T15:37:44","date_gmt":"2024-12-22T11:37:44","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4154"},"modified":"2024-12-22T15:37:44","modified_gmt":"2024-12-22T11:37:44","slug":"sky-cdg025d-x3-4-20ma","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/sky-cdg025d-x3-4-20ma\/","title":{"rendered":"SKY\u00ae CDG025D-X3, 4-20mA"},"content":{"rendered":"\n<p>Capacitance Manometers<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Full scale 0.1 \u2026 1000 Torr \/ mbar<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 61%\"><div class=\"wp-block-media-text__content\">\n<p>The INFICON SKY CDG025D Capacitance Diaphragm Gauge line of highly accurate temperature compensated manometers is designed for stable performance in harsh manufacturing tool environments.&nbsp;<\/p>\n\n\n\n<p>Advanced digital electronics improve gauge performance and offer easy handling features such as one pushbutton zero function.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-239.png\" alt=\"\" class=\"wp-image-4156 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-239.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-239-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p> New Version with 2wire current Loop is now available. The corrosion resistant ultra pure ceramic sensor provides excellent zero stability with a long life expectancy of several million pressure cycles, including atmospheric bursts. A unique sensor shielding (patent pending) protects the gauge from process contamination. A robust mechanical design and digital electronics improve EMC compatibility, long term stability and temperature compensation.\u00a0<\/p>\n\n\n\n<p>The CDG025D sets new standards for fast stability after power on and fast recovery from atmospheric pressure exposure.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Full scale ranges from 100 mTorr \u2026 1000 Torr<\/li>\n\n\n\n<li>Fast stability after power on<\/li>\n\n\n\n<li>Fast recovery from atmospheric pressure<\/li>\n\n\n\n<li>Corrosion resistant ceramic sensor<\/li>\n\n\n\n<li>Excellent long term signal stability<\/li>\n\n\n\n<li>Temperature compensated<\/li>\n\n\n\n<li>Sensor double protected from contamination<\/li>\n\n\n\n<li>One pushbutton zero function<\/li>\n\n\n\n<li>Interface with 2-wire current loop<\/li>\n\n\n\n<li>Long cable distance (&lt;300m)<\/li>\n\n\n\n<li>Low energy gauge<\/li>\n\n\n\n<li>Remote zero included<\/li>\n\n\n\n<li>Clean room compliant<\/li>\n\n\n\n<li>Status LED<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Chemical vacuum<\/li>\n\n\n\n<li>Energy application<\/li>\n\n\n\n<li>Industrial vacuum equipment<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/03\\\/7793-SKY%20CDG025D-X3%2C%204-20mA.jpg?v=1-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:672px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: SKY\\u00ae CDG025D-X3, 4-20mA Ordering Information&quot;,&quot;alt&quot;:&quot;SKY\\u00ae CDG025D-X3, 4-20mA Ordering Information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/03\/7793-SKY%20CDG025D-X3%2C%204-20mA.jpg?v=1-0\" alt=\"SKY\u00ae CDG025D-X3, 4-20mA Ordering Information\" style=\"width:672px;height:auto\" title=\"SKY\u00ae CDG025D-X3, 4-20mA Ordering Information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: SKY\u00ae CDG025D-X3, 4-20mA Ordering Information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p> <\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/7778\/download\/SKY%C2%AE-CDG025D-Brochure.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SKY\u00ae CDG025D Vacuum Gauge<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5508\/download\/SKY%C2%AE-CDG25D-X3-4-20mA-Current-Loop-Datasheet.pdf?v=4&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\"> SKY\u00ae CDG025D-X3 4-20mA current loop<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/sky-cdg025d-x3-4-20ma\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacitance Manometers Full scale 0.1 \u2026 1000 Torr \/ mbar The INFICON SKY CDG025D Capacitance Diaphragm Gauge line of highly accurate temperature compensated manometers is designed for stable performance in harsh manufacturing tool environments.&nbsp; Advanced digital electronics improve gauge performance and offer easy handling features such as one pushbutton zero function. New Version with 2wire [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4154"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4154"}],"version-history":[{"count":4,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4154\/revisions"}],"predecessor-version":[{"id":4159,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4154\/revisions\/4159"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4154"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}