{"id":4161,"date":"2024-12-22T15:37:51","date_gmt":"2024-12-22T11:37:51","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4161"},"modified":"2024-12-22T15:37:51","modified_gmt":"2024-12-22T11:37:51","slug":"sky-cdg045d","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/sky-cdg045d\/","title":{"rendered":"SKY\u00ae CDG045D"},"content":{"rendered":"\n<p>Capacitance Manometers<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>45\u00b0C temperature controlled, full scale 0.05 \u2026 1000 Torr \/ mbar<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 59%\"><div class=\"wp-block-media-text__content\">\n<p>INFICON SKY CDG045D manometers are your best choice for high accurate total pressure measurement and control.&nbsp;<\/p>\n\n\n\n<p>CDG045D gauges are temperature controlled at 45 \u00b0C for superior signal stability and repeatability. <\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-240.png\" alt=\"\" class=\"wp-image-4162 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-240.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-240-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>They are available for full scale ranges from 50 mTorr to 1000 Torr, with all common flange types and fieldbus interfaces and provide a linear 0 to 10 V, gas type independent, pressure signal. INFICON capacitance manometers use an ultra pure alumina ceramic diaphragm which is corrosion proof.&nbsp;<\/p>\n\n\n\n<p>The advantages of the ceramic sensor are better signal stability, faster recovery from atmosphere, short warm up time and an extraordinary lifetime. INFICON CDG are high quality, cost effective pressure sensors for demanding vacuum applications.<\/p>\n\n\n\n<p>Also available with<strong>&nbsp;PROFINET<\/strong>\u00ae&nbsp;digital interface and with current loop&nbsp;<strong>4 \u2026 20 mA<\/strong>!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Lower CoO (cost of ownership), 50% faster warm up, energy efficient low power consumption<\/li>\n\n\n\n<li>Easy integration, wide variety of full scales, flanges and interfaces, standard with two set points<\/li>\n\n\n\n<li>Easy one push button or remote signal zero command, zero offset adjustable<\/li>\n\n\n\n<li>Diagnostic port for quick service and maintenance<\/li>\n\n\n\n<li>Two year warranty, longer life time with advanced heating concept and gauge protection<\/li>\n\n\n\n<li>No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications<\/li>\n\n\n\n<li>Compliance &amp; standards: CE, EN, UL, SEMI, RoHS<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Etch, CVD, PVD and other semiconductor production processes<\/li>\n\n\n\n<li>Chemical and corrosive vacuum processes<\/li>\n\n\n\n<li>General thin film and vacuum processes<\/li>\n\n\n\n<li>Reference sensor for monitoring of test instruments according to international standards<\/li>\n\n\n\n<li>Transfer standard for traceability measurements<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/08\\\/7788-CDG045D%20Ordering%20information.jpg?v=1-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:null,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: SKY\\u00ae CDG045D Ordering information&quot;,&quot;alt&quot;:&quot;SKY\\u00ae CDG045D Ordering information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/08\/7788-CDG045D%20Ordering%20information.jpg?v=1-0\" alt=\"SKY\u00ae CDG045D Ordering information\" title=\"SKY\u00ae CDG045D Ordering information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: SKY\u00ae CDG045D Ordering information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3546\/download\/SKY%C2%AE-CDG045D-Brochure.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SKY\u00ae CDG045D Vacuum Gauge<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5705\/download\/SKY%C2%AE-CDG045D-Datasheet.pdf?v=14&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SKY\u00ae CDG045D<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/sky-cdg045d\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacitance Manometers 45\u00b0C temperature controlled, full scale 0.05 \u2026 1000 Torr \/ mbar INFICON SKY CDG045D manometers are your best choice for high accurate total pressure measurement and control.&nbsp; CDG045D gauges are temperature controlled at 45 \u00b0C for superior signal stability and repeatability. They are available for full scale ranges from 50 mTorr to 1000 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4161"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4161"}],"version-history":[{"count":3,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4161\/revisions"}],"predecessor-version":[{"id":4171,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4161\/revisions\/4171"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4161"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}