{"id":4172,"date":"2024-12-22T15:38:04","date_gmt":"2024-12-22T11:38:04","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4172"},"modified":"2024-12-22T15:38:04","modified_gmt":"2024-12-22T11:38:04","slug":"sky-cdg160d","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/sky-cdg160d\/","title":{"rendered":"SKY\u00ae CDG160D"},"content":{"rendered":"\n<p>Capacitance Manometers<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>160\u00b0C temperature controlled, full scale 1 \u2026 1000 Torr \/ mbar<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 60%\"><div class=\"wp-block-media-text__content\">\n<p>INFICON SKY CDG160D high temperature manometers are your best choice for accurate total pressure measurement and control.&nbsp;<\/p>\n\n\n\n<p>CDG160D gauges are temperature controlled at 160 \u00b0C for superior performance in demanding semiconductor and plasma processes. <\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-242.png\" alt=\"\" class=\"wp-image-4173 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-242.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-242-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>They are available for full scale ranges from 1 Torr to 1000 Torr, with all common flange types and fieldbus interfaces and provide a linear 0 to 10 V, gas type independent, pressure signal. INFICON capacitance manometers use an ultra pure alumina ceramic diaphragm which is corrosion proof.&nbsp;<\/p>\n\n\n\n<p>The advantages of the ceramic sensor are better signal stability, faster recovery from atmosphere, short warm up time and an extraordinary lifetime. INFICON CDG are high quality, cost effective pressure sensors for demanding semiconductor, plasma and vacuum applications.<\/p>\n\n\n\n<p>Also available with\u00a0<strong>EtherCAT<\/strong>\u00a0digital interface!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Lower CoO (cost of ownership), 50% faster warm up, energy efficient low power consumption<\/li>\n\n\n\n<li>Easy integration, wide variety of full scales, flanges and interfaces, standard with two set points<\/li>\n\n\n\n<li>Easy one push button or remote signal zero command, zero offset adjustable<\/li>\n\n\n\n<li>Diagnostic port for quick service and maintenance<\/li>\n\n\n\n<li>Two year warranty, longer life time with heating concept and gauge protection<\/li>\n\n\n\n<li>No long term recalibration due to excellent signal stability and repeatability, even in harsh plasma applications<\/li>\n\n\n\n<li>Compliance &amp; standards: CE, EN, UL, SEMI, RoHS<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Etch, CVD, PVD and other semiconductor production processes<\/li>\n\n\n\n<li>Chemical and corrosive high temperature processes<\/li>\n\n\n\n<li>General thin film and vacuum processes requiring gauge protection<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/04\\\/7784-CDG160_200D%20Ordering%20information.jpg?v=1-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:null,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: CDG160_200D Ordering information&quot;,&quot;alt&quot;:&quot;CDG160_200D Ordering information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/04\/7784-CDG160_200D%20Ordering%20information.jpg?v=1-0\" alt=\"CDG160_200D Ordering information\" title=\"CDG160_200D Ordering information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: CDG160_200D Ordering information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5307\/download\/SKY%C2%AE-CDG100-200D-Brochure.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SKY\u00ae CDG100D, CDG160D, CDG200D Vacuum Gauge<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10140\/download\/Vacuum-Instrumentation-with-EtherCAT-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Vacuum Instrumentation with EtherCAT<\/a><\/strong>. Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5527\/download\/SKY%C2%AE-CDG160D-CDG200D-Datasheet.pdf?v=6&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SKY\u00ae CDG160D \/ CDG200D<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/sky-cdg160d\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacitance Manometers 160\u00b0C temperature controlled, full scale 1 \u2026 1000 Torr \/ mbar INFICON SKY CDG160D high temperature manometers are your best choice for accurate total pressure measurement and control.&nbsp; CDG160D gauges are temperature controlled at 160 \u00b0C for superior performance in demanding semiconductor and plasma processes. They are available for full scale ranges from [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4172"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4172"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4172\/revisions"}],"predecessor-version":[{"id":4174,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4172\/revisions\/4174"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4172"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}