{"id":4221,"date":"2024-12-22T15:38:30","date_gmt":"2024-12-22T11:38:30","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4221"},"modified":"2024-12-22T15:38:30","modified_gmt":"2024-12-22T11:38:30","slug":"spot-cds500d","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/spot-cds500d\/","title":{"rendered":"Spot\u2122 CDS500D"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"alignright size-full is-resized\"><a href=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-252.png\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-252.png\" alt=\"\" class=\"wp-image-4224\" style=\"width:430px;height:auto\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-252.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-252-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/a><\/figure><\/div>\n\n\n<p>Capacitance Manometers<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>Full scale 10 \u2026 1000 Torr \/ mbar<\/strong><\/p>\n\n\n\n<p>The Spot CDS500D ceramic capacitance diaphragm sensor is designed for integration into the limited space in your specific vacuum instruments and systems.\u00a0<\/p>\n\n\n\n<p>The miniature sensor offers a high accuracy and the alumina ceramic cell and the weldable stainless steel feedthrough are all alumina coated. The sensor electronics provides a digital SPI interface for easy integration.\u00a0<\/p>\n\n\n\n<p>The sensor features a fast data cycle time for instant response to pressure changes, outstanding repeatability and long-term stability.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>The miniature sensor offers a high accuracy<\/li>\n\n\n\n<li>Excellent repeatability and long-term stability<\/li>\n\n\n\n<li>Weldable feedthrough for custom integration and calibration, or welded custom flange for integration of factory calibrated sensor<\/li>\n\n\n\n<li>Sensor electronics with SPI interface for easy integration<\/li>\n\n\n\n<li>Fast response time<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>For integration into custom vacuum instrumentation and systems<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p> <strong><a href=\"https:\/\/www.inficon.com\/media\/5737\/download\/Spot%E2%84%A2-CDS500D-Datasheet.pdf?v=5&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">SpotTM CDS500D<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/spot-cds500d\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Capacitance Manometers Full scale 10 \u2026 1000 Torr \/ mbar The Spot CDS500D ceramic capacitance diaphragm sensor is designed for integration into the limited space in your specific vacuum instruments and systems.\u00a0 The miniature sensor offers a high accuracy and the alumina ceramic cell and the weldable stainless steel feedthrough are all alumina coated. The [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4221"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4221"}],"version-history":[{"count":5,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4221\/revisions"}],"predecessor-version":[{"id":4228,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4221\/revisions\/4228"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4221"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}