{"id":4284,"date":"2024-12-22T15:35:23","date_gmt":"2024-12-22T11:35:23","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4284"},"modified":"2024-12-22T15:35:23","modified_gmt":"2024-12-22T11:35:23","slug":"pcg55x-pirani-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/pcg55x-pirani-gauges\/","title":{"rendered":"PCG55x Pirani Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>ATM TO MEDIUM VACUUM GAUGE<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 62%\"><div class=\"wp-block-media-text__content\">\n<p>The INFICON Pirani Capacitance Diaphragm Gauge (PCG55x) combines the INFICON Pirani technology with the advantages of a ceramic capacitance diaphragm sensor in a single product.<\/p>\n\n\n\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-265.png\" alt=\"\" class=\"wp-image-4285 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-265.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-265-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>In the measurement range between 10 mbar and atmosphere the capacitance diaphragm technology provides gas-type independent, highly accurate values for reliable pressure measurement. The PCG55x offers also a variety of features which allows the right product configuration for the demanded application.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Gas type independent above 10 mbar \u2013 allows safe venting with any gas mixture<\/li>\n\n\n\n<li>High accuracy and reproducibility at atmosphere \u2013 for reliable, fast atmospheric pressure detection<\/li>\n\n\n\n<li>Versatile of mounting orientation \u2013 provides engineering freedom in tool design<\/li>\n\n\n\n<li>Available with Tungsten (PCG550) or Nickel (PCG552) filament or with a fully ceramic coated (PCG554) sensor unit for highly corrosive applications<\/li>\n\n\n\n<li>Latest EtherCAT protocol Standard ETG.5003.2080 S (R) V1.3.0<\/li>\n\n\n\n<li>Easy to exchange plug &amp; play sensor element with on-board calibration data \u2013 guarantees high reproducibility and low cost of ownership<\/li>\n\n\n\n<li>Selectable output signal for easy integration<\/li>\n\n\n\n<li>Optional atmospheric switch, display and digital interfaces<\/li>\n\n\n\n<li>Compliance &amp; standards: CE, EN, UL, CSA, RoHS<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Load Lock control<\/li>\n\n\n\n<li>Fore vacuum pressure measurement<\/li>\n\n\n\n<li>Safety circuits in vacuum systems<\/li>\n\n\n\n<li>General vacuum measurement and control in the medium and rough vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td colspan=\"2\"><strong>PCG550 Tungsten<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-001<\/em><\/td><td>Clamping ring DN 10-16 ISO-KF<\/td><\/tr><tr><td><em>350-050<\/em><\/td><td>Power Supply, PxG5xx,G-Cable FCC,1.8m&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG552 Nickel<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-001<\/em><\/td><td>Clamping ring DN 10-16 ISO-KF<\/td><\/tr><tr><td><em>350-050<\/em><\/td><td>Power Supply, PxG5xx,G-Cable FCC,1.8m&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG554 ceramic coated<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-001<\/em><\/td><td>Clamping ring DN 10-16 ISO-KF<\/td><\/tr><tr><td><em>350-050<\/em><\/td><td>Power Supply, PxG5xx,G-Cable FCC,1.8m&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG550 Tungsten<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-097<\/em><\/td><td>Centering ring with fine filter DN 16 KF&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG552 Nickel<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-097<\/em><\/td><td>Centering ring with fine filter DN 16 KF&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG554 ceramic coated<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>211-097<\/em><\/td><td>Centering ring with fine filter DN 16 KF&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG550 Tungsten<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>303-333<\/em><\/td><td>Diagnostic cable 1.9m (P3)&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG552 Nickel<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>303-333<\/em><\/td><td>Diagnostic cable 1.9m (P3)&nbsp;<\/td><\/tr><tr><td colspan=\"2\"><strong>PCG554 ceramic coated<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>303-333<\/em><\/td><td>Diagnostic cable 1.9m (P3)<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/04\\\/7794-PCG55X%20PN.png?v=1-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:840px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: PCG55X PN&quot;,&quot;alt&quot;:&quot;PCG55X PN&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/04\/7794-PCG55X%20PN.png?v=1-0\" alt=\"PCG55X PN\" style=\"width:840px;height:auto\" title=\"PCG55X PN\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: PCG55X PN\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3607\/download\/Pirani-Family-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">The Pirani Family<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10140\/download\/Vacuum-Instrumentation-with-EtherCAT-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Vacuum Instrumentation with EtherCAT.<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5669\/download\/PCG55x-Pirani-Capacitance-Diaphragm-Gauge.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">PCG550, PCG552, PCG554 Pirani Capacitance Diaphragm Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/pcg55x\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ATM TO MEDIUM VACUUM GAUGE The INFICON Pirani Capacitance Diaphragm Gauge (PCG55x) combines the INFICON Pirani technology with the advantages of a ceramic capacitance diaphragm sensor in a single product. In the measurement range between 10 mbar and atmosphere the capacitance diaphragm technology provides gas-type independent, highly accurate values for reliable pressure measurement. The PCG55x [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4284"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4284"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4284\/revisions"}],"predecessor-version":[{"id":4286,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4284\/revisions\/4286"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4284"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}