{"id":4297,"date":"2024-12-22T15:37:00","date_gmt":"2024-12-22T11:37:00","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4297"},"modified":"2024-12-22T15:37:00","modified_gmt":"2024-12-22T11:37:00","slug":"psg010-psg017-psg018-pirani-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/psg010-psg017-psg018-pirani-gauges\/","title":{"rendered":"PSG010, PSG017 &amp; PSG018 Pirani Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Pirani passive gauge heads for VGC094<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 60%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<p>The gauge heads PSG010, PSG017 and PSG018 are long-established passive Pirani gauges intended to operate with the Vacuum Gauge Controller VGC094. They are designed for vacuum measurement of gases in the pressure range of 8\u00d710<sup>-4<\/sup>&nbsp;to 1000 mbar. The compact metal design provides a robust solution suitable for general vacuum applications.&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-268.png\" alt=\"\" class=\"wp-image-4298 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-268.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-268-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>While PSG010 is suited for general vacuum applications, PSG017 and PSG018 respond to needs of demanding applications requiring bake-out temperature up to 250 \u00b0C or high ionizing radiation resistance, thanks to a metal sealing design. PSG017 has a Nickel filament suitable for corrosive media applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Elastomer (PSG010) or metal-sealed (PSG017, PSG018) design<\/li>\n\n\n\n<li>Specified high measurement accuracy and repeatability<\/li>\n\n\n\n<li>Bake-out temperature up to 100 \u00b0C (PSG010) \/ 250 \u00b0C (PSG017, PSG018)<\/li>\n\n\n\n<li>Ionizing radiation resistant up to 10<sup>6<\/sup>\u00a0Gy (PSG017, PSG018)<\/li>\n\n\n\n<li>Corrosion resistance with Ni filament (PSG017)<\/li>\n\n\n\n<li>Cable length up to 100 m (500 m with PI 300 DL\/CP 300 T11L)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>General vacuum measurement and control for demanding and\/or high temperature applications from low to the high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Operating Units<\/h2>\n\n\n\n<ul>\n<li class=\"has-medium-font-size\">Vacuum Gauge Controller VGC094<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>&nbsp;<\/td><td><strong>PSG010<\/strong><\/td><\/tr><tr><td>350-400<\/td><td>DN 10 ISO-KF<\/td><\/tr><tr><td>&nbsp;<\/td><td><strong>PSG017<\/strong><\/td><\/tr><tr><td>350-430<\/td><td>DN 16 ISO-KF<\/td><\/tr><tr><td>350-431<\/td><td>DN 16 CF-F<\/td><\/tr><tr><td>&nbsp;<\/td><td><strong>PSG018<\/strong><\/td><\/tr><tr><td>350-420<\/td><td>DN 16 ISO-KF<\/td><\/tr><tr><td>350-424<\/td><td>DN 16 CF-F<\/td><\/tr><tr><td>350-423<\/td><td>DN 40 CF-F<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/9718\/download\/PSG010,-PSG017,-PSG018-Pirani-Gauges-.pdf?v=4&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">PSG010, PSG017, PSG018 Pirani Gauges &#8211; Passive<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/psg01x\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Pirani passive gauge heads for VGC094 The gauge heads PSG010, PSG017 and PSG018 are long-established passive Pirani gauges intended to operate with the Vacuum Gauge Controller VGC094. They are designed for vacuum measurement of gases in the pressure range of 8\u00d710-4&nbsp;to 1000 mbar. The compact metal design provides a robust solution suitable for general vacuum [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4297"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4297"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4297\/revisions"}],"predecessor-version":[{"id":4300,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4297\/revisions\/4300"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4297"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}