{"id":4308,"date":"2024-12-22T15:39:11","date_gmt":"2024-12-22T11:39:11","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4308"},"modified":"2024-12-22T15:39:11","modified_gmt":"2024-12-22T11:39:11","slug":"trigon-bag552-hot-ionization-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/trigon-bag552-hot-ionization-gauges\/","title":{"rendered":"Trigon\u2122 BAG552 Hot Ionization Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Medium to Ultra High Vacuum Single Gauge<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 60%\"><div class=\"wp-block-media-text__content\">\n<p>For applications that require stand-alone hot ion gauge technology, the Trigon\u2122 family includes the single technology Bayard-Alpert Hot Ion Gauge BAG552.<\/p>\n\n\n\n<p>The BAG552 is designed for vacuum measurement of gases in the pressure range 5 \u00d7 10<sup>-10<\/sup>&nbsp;&#8230;&nbsp;2 x 10<sup>-2<\/sup>&nbsp;mbar. The supported dual filament offers superior accuracy, repeatability and longevity. The BAG552 can also be operated in conjunction with the INFICON Vacuum Gauge Controller series&nbsp;<a href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/vgc50x\">VGC501<\/a>,&nbsp;<a href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/vgc50x\">VGC502<\/a>,&nbsp;<a href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/vgc50x\">VGC503<\/a>.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-270.png\" alt=\"\" class=\"wp-image-4309 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-270.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-270-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">VacXplor\u2122 Software<\/h2>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 27%\"><div class=\"wp-block-media-text__content\">\n<p>VacXplor, our modular user software is designed to enhance your experience with INFICON Trigon Gauges. VacXplor offers a unified interface, dynamic data visualization, and advanced customization options, all without the need for administrator rights for installation.&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link has-text-color has-link-color wp-element-button\" href=\"https:\/\/www.inficon.com\/media\/10881\/download\/VacXplor-Software.zip\" style=\"color:#3c58d9\" target=\"_blank\" rel=\"noreferrer noopener\">Download VacXplor\u2122 here<\/a><\/div>\n<\/div>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/www.inficon.com\/uploads\/media\/294x\/00\/10810-Icon%20-%20VacXplor%201.png?v=2-0\" alt=\"Icon - VacXplor 1\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Pure Bayard-Alpert measuring system for a wide UHV &amp; HV measurement range\u00a0<\/li>\n\n\n\n<li>2 filaments for Bayard-Alpert system\u00a0<\/li>\n\n\n\n<li>Galvanic isolated electronics to avoid electric stray current\u00a0<\/li>\n\n\n\n<li>Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream\u00a0<\/li>\n\n\n\n<li>Extended bakeability due to removable calibration data chips\u00a0<\/li>\n\n\n\n<li>Set point relays\u00a0<\/li>\n\n\n\n<li>Bright &amp; big OLED display (90\u00b0 rotateable) with user interface\u00a0<\/li>\n\n\n\n<li>Analog output, RS232C serial interface, EtherCAT\u00ae\u00a0<\/li>\n\n\n\n<li>Usable in conjunction with VGC50x Controller series\u00a0<\/li>\n\n\n\n<li>RoHS compliance<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Pressure measurement in Semiconductor processes<\/li>\n\n\n\n<li>Industrial coating<\/li>\n\n\n\n<li>General vacuum measurement and control on systems in the high to ultra high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/02\\\/9692-BAG552%20Ordering%20Information_V01_Neu.png?v=2-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:836px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: BAG552 Ordering Information&quot;,&quot;alt&quot;:&quot;BAG552 Ordering Information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/02\/9692-BAG552%20Ordering%20Information_V01_Neu.png?v=2-0\" alt=\"BAG552 Ordering Information\" style=\"width:836px;height:auto\" title=\"BAG552 Ordering Information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: BAG552 Ordering Information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Part Number<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>352-420<\/td><td>BAG552 Spare sensor head, 25KF<\/td><\/tr><tr><td>352-421<\/td><td>BAG552 Spare sensor head, 40CF<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/9691\/download\/Trigon%E2%84%A2-Hot-Ion-Single-and-Combi-Vacuum-Gauges-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Trigon\u2122 Hot Ion Single &amp; Combi Vacuum Gauges<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10140\/download\/Vacuum-Instrumentation-with-EtherCAT-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Vacuum Instrumentation with EtherCAT.<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10889\/download\/Trigon%E2%84%A2-BAG552-SingleGauge-Datasheet.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Trigon\u2122 BAG552 SingleGauge Bayard-Alpert Hot Ion Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/bag552-trigon\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Medium to Ultra High Vacuum Single Gauge For applications that require stand-alone hot ion gauge technology, the Trigon\u2122 family includes the single technology Bayard-Alpert Hot Ion Gauge BAG552. The BAG552 is designed for vacuum measurement of gases in the pressure range 5 \u00d7 10-10&nbsp;&#8230;&nbsp;2 x 10-2&nbsp;mbar. The supported dual filament offers superior accuracy, repeatability and [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4308"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4308"}],"version-history":[{"count":3,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4308\/revisions"}],"predecessor-version":[{"id":4312,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4308\/revisions\/4312"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4308"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}