{"id":4314,"date":"2024-12-22T15:39:19","date_gmt":"2024-12-22T11:39:19","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4314"},"modified":"2024-12-22T15:39:19","modified_gmt":"2024-12-22T11:39:19","slug":"trigon-bcg552-hot-ionization-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/trigon-bcg552-hot-ionization-gauges\/","title":{"rendered":"Trigon\u2122 BCG552 Hot Ionization Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>ATM to Ultra High Vacuum TripleGauge\u00ae<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 60%\"><div class=\"wp-block-media-text__content\">\n<p>The TripleGauge\u00ae BCG552 combines 3 vacuum sensing elements in one sensor flange. This flagship of the new Trigon<sup>TM<\/sup>\u00a0family offers a extremely wide measurement range from UHV (5 x10<sup>-10<\/sup>) up to ATM (1500 mbar). With its added ATM sensor, BCG552 is well-suited for differential pressure measurement and for use as vacuum switch in several applications.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-271.png\" alt=\"\" class=\"wp-image-4316 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-271.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-271-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>The supported Bayard-Alpert dual filament offers superior accuracy, repeatability and longevity in the UHV and HV range, while the miniaturized capacitance diaphragm gauge has superior accuracy in the ATM range and is gas type independent.<\/p>\n\n\n\n<p><a href=\"https:\/\/www.inficon.com\/en\/news\/vacxplor\">Discover more about VacXplor<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">VacXplor\u2122 Software<\/h2>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 27%\"><div class=\"wp-block-media-text__content\">\n<p>VacXplor, our modular user software is designed to enhance your experience with INFICON Trigon Gauges. VacXplor offers a unified interface, dynamic data visualization, and advanced customization options, all without the need for administrator rights for installation.&nbsp;<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link has-text-color has-link-color wp-element-button\" href=\"https:\/\/www.inficon.com\/media\/10881\/download\/VacXplor-Software.zip\" style=\"color:#3c58d9\" target=\"_blank\" rel=\"noreferrer noopener\">Download VacXplor\u2122 here<\/a><\/div>\n<\/div>\n<\/div><figure class=\"wp-block-media-text__media\"><img decoding=\"async\" src=\"https:\/\/www.inficon.com\/uploads\/media\/294x\/00\/10810-Icon%20-%20VacXplor%201.png?v=2-0\" alt=\"Icon - VacXplor 1\"\/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>3 + 1 sensing elements for extremely wide measurement range, cost reduction &amp; space savings<\/li>\n\n\n\n<li>2 filaments for Bayard-Alpert system\u00a0<\/li>\n\n\n\n<li>Gas type independent pressure measurement above 10 Torr provides more reliable load lock control for any gas mixtures<\/li>\n\n\n\n<li>Differential pressure measurement eliminates uncertainty related to atmospheric pressure changes\u00a0<\/li>\n\n\n\n<li>Automatic high vacuum Pirani adjustment reduces operator interventions\u00a0<\/li>\n\n\n\n<li>Galvanic isolated electronics to avoid electric stray current\u00a0<\/li>\n\n\n\n<li>Sliding emission mode to avoid pressure jumps and freeze when switching the emission stream\u00a0<\/li>\n\n\n\n<li>Set point relays\u00a0<\/li>\n\n\n\n<li>Bright &amp; big OLED display (90\u00b0 rotatable) with user interface\u00a0<\/li>\n\n\n\n<li>Analog output, RS232C serial interface, EtherCAT\u00ae\u00a0<\/li>\n\n\n\n<li>Usable in conjunction with VGC50x Controller series\u00a0<\/li>\n\n\n\n<li>Backwards compatible to TripleGauge\u00ae BCG450\u00a0<\/li>\n\n\n\n<li>RoHS compliance<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Pressure measurement in Semiconductor processes, transfer and loadlock chambers<\/li>\n\n\n\n<li>Industrial coating<\/li>\n\n\n\n<li>General vacuum measurement and control on systems in the low to ultra high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/03\\\/9693-BCG552%20Ordering%20Information_V01_Neu.png?v=2-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:788px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: BCG552 Ordering Information&quot;,&quot;alt&quot;:&quot;BCG552 Ordering Information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/03\/9693-BCG552%20Ordering%20Information_V01_Neu.png?v=2-0\" alt=\"BCG552 Ordering Information\" style=\"width:788px;height:auto\" title=\"BCG552 Ordering Information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: BCG552 Ordering Information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Part Number<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>354-423<\/td><td>BCG552 Spare sensor head, KF25<\/td><\/tr><tr><td>354-424<\/td><td>BCG552 Spare sensor head, CF40<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/9691\/download\/Trigon%E2%84%A2-Hot-Ion-Single-and-Combi-Vacuum-Gauges-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Trigon\u2122 Hot Ion Single &amp; Combi Vacuum Gauges<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10140\/download\/Vacuum-Instrumentation-with-EtherCAT-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Vacuum Instrumentation with EtherCAT.<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10890\/download\/Trigon%E2%84%A2-BCG552-TripleGauge-Datasheet.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Trigon\u2122 BCG552 TripleGauge\u00ae Bayard-Alpert Pirani Capacitance Diaphragm Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-2 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/bcg552-trigon\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ATM to Ultra High Vacuum TripleGauge\u00ae The TripleGauge\u00ae BCG552 combines 3 vacuum sensing elements in one sensor flange. This flagship of the new TrigonTM\u00a0family offers a extremely wide measurement range from UHV (5 x10-10) up to ATM (1500 mbar). With its added ATM sensor, BCG552 is well-suited for differential pressure measurement and for use as [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4314"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4314"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4314\/revisions"}],"predecessor-version":[{"id":4317,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4314\/revisions\/4317"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4314"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}