{"id":4356,"date":"2024-12-22T15:31:37","date_gmt":"2024-12-22T11:31:37","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4356"},"modified":"2024-12-22T15:31:53","modified_gmt":"2024-12-22T11:31:53","slug":"bpg402-sx-hot-ionization-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/bpg402-sx-hot-ionization-gauges\/","title":{"rendered":"BPG402-Sx Hot Ionization Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>ATM to Ultra High Vacuum Gauge<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 53%\"><div class=\"wp-block-media-text__content\">\n<p>The INFICON Bayard-Alpert Pirani Combination Gauge, BPG402-S, functions as two gauges in a single compact unit measuring from 5\u00d710<sup>-10<\/sup>&nbsp;mbar to atmosphere (3.8\u00d710<sup>-10<\/sup>&nbsp;Torr to atmosphere).&nbsp;<\/p>\n\n\n\n<p>Combining technologies reduces the complexity of installation, setup, and integration. <\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-282.png\" alt=\"\" class=\"wp-image-4357 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-282.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-282-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>Choose the BPG402-S with two yttrium oxide coated iridium filaments for affordable and repeatable process to base pressure measurements in one economical package. Sensing elements with on-board calibration data guarantees high reproducibility when exchanging sensors.<\/p>\n\n\n\n<p>Also available with the EtherCAT digital interface!<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Extremely wide measurement range from 5\u00d710<sup>-10<\/sup>\u00a0mbar to atmosphere (3.8\u00d710<sup>-10\u00a0<\/sup>Torr to atmosphere)<\/li>\n\n\n\n<li>Excellent repeatability in the process pressure range from 10<sup>-8<\/sup>\u00a0\u2026 10<sup>-2<\/sup>\u00a0mbar of 5%<\/li>\n\n\n\n<li>Pirani interlock protects the filament from premature burnout<\/li>\n\n\n\n<li>Two long-life yttrium oxide coated iridium filaments<\/li>\n\n\n\n<li>Optional graphic display and Fieldbus interfaces available<\/li>\n\n\n\n<li>Automatic high vacuum Pirani adjustment reduces operator interventions<\/li>\n\n\n\n<li>Easy to exchange sensing element with on-board calibration data guarantees high reproducibility<\/li>\n\n\n\n<li>RoHS compliance<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Pressure measurement in semiconductor process and transfer chambers<\/li>\n\n\n\n<li>Industrial coating<\/li>\n\n\n\n<li>General vacuum measurement and control in the low to ultra high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>353-570<\/em><\/td><td>BPG402-S DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-571<\/em><\/td><td>BPG402-S DN 40 CF-R<\/td><\/tr><tr><td><em>353-572<\/em><\/td><td>BPG402-S LCD, DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-573<\/em><\/td><td>BPG402-S LCD, DN 40 CF-R<\/td><\/tr><tr><td><em>353-578<\/em><\/td><td>BPG402-SL long tube DN 40 CF-R<\/td><\/tr><tr><td><em>353-574<\/em><\/td><td>BPG402-SP PBus, DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-575<\/em><\/td><td>BPG402-SP PBus, DN 40 CF-R<\/td><\/tr><tr><td><em>353-576<\/em><\/td><td>BPG402-SD DNet, DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-577<\/em><\/td><td>BPG402-SD DNet, DN 40 CF-R<\/td><\/tr><tr><td><em>353-590<\/em><\/td><td>BPG402-SE ECAT, DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-591<\/em><\/td><td>BPG402-SE ECAT, DN 40 CF-R<\/td><\/tr><tr><td><em>353-596<\/em><\/td><td>BPG402-SE ECAT, DN 25 ISO-KF<\/td><\/tr><tr><td><em>353-597<\/em><\/td><td>BPG402-SE ECAT, DN 40 CF-R<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/3567\/download\/Hot-Ion-Gauge-Brochure.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Hot Ion Vacuum Gauges<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/10140\/download\/Vacuum-Instrumentation-with-EtherCAT-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Vacuum Instrumentation with EtherCAT.<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5492\/download\/BPG402-S-Datasheet.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">BPG402-S Bayard-Alpert Pirani Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/bpg402-sx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n\n\n\n<div class=\"wp-block-media-text is-stacked-on-mobile\" style=\"grid-template-columns:43% auto\"><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-279.png\" alt=\"\" class=\"wp-image-4337 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-279.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-279-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><div class=\"wp-block-media-text__content\">\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">More Flexibility. Better Stability.<\/h2>\n\n\n\n<p>Sliding emission mode, removable calibration chip, galvanic isolated electronics, optional OLED display (90\u00b0 rotatable), and more.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link has-text-color has-link-color wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4319\" style=\"color:#2246b1\" target=\"_blank\" rel=\"noreferrer noopener\">Upgrade Now<\/a><\/div>\n<\/div>\n\n\n\n<p><\/p>\n<\/div><\/div>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity is-style-wide\"\/>\n","protected":false},"excerpt":{"rendered":"<p>ATM to Ultra High Vacuum Gauge The INFICON Bayard-Alpert Pirani Combination Gauge, BPG402-S, functions as two gauges in a single compact unit measuring from 5\u00d710-10&nbsp;mbar to atmosphere (3.8\u00d710-10&nbsp;Torr to atmosphere).&nbsp; Combining technologies reduces the complexity of installation, setup, and integration. Choose the BPG402-S with two yttrium oxide coated iridium filaments for affordable and repeatable process [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4356"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4356"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4356\/revisions"}],"predecessor-version":[{"id":4359,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4356\/revisions\/4359"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4356"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}