{"id":4372,"date":"2024-12-22T15:31:10","date_gmt":"2024-12-22T11:31:10","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4372"},"modified":"2024-12-22T15:31:10","modified_gmt":"2024-12-22T11:31:10","slug":"bag302-hot-ionization-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/bag302-hot-ionization-gauges\/","title":{"rendered":"BAG302 Hot Ionization Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Medium to Ultra High Vacuum Gauge<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 52%\"><div class=\"wp-block-media-text__content\">\n<p>The INFICON single Bayard-Alpert Hot Ion gauge BAG302 covers a wide measurement range from 1.3 \u00d7 10<sup>-9<\/sup>&nbsp;to 6.7\u00d710<sup>-2<\/sup>&nbsp;mbar (1 \u00d7 10<sup>-9<\/sup>&nbsp;to 5 \u00d7 10<sup>-2<\/sup>&nbsp;Torr).&nbsp;<\/p>\n\n\n\n<p>The compact All-In-One Hot Ion gauge BAG302 offers an easy to exchange dual filament sensor, a built in OLED display, set-point relay and a log-linear analogue output as well as an integrated RS485 digital interface for increased integration flexibility.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-285.png\" alt=\"\" class=\"wp-image-4373 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-285.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-285-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>These features combined with the rugged design makes the BAG302 an affordable and repeatable process to base pressure measurement instrument of its own and provides a high value\/ low cost of ownership choice.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Wide measurement range from 1.3 \u00d7 10<sup>-9<\/sup>\u00a0to 6.7\u00d710<sup>-2<\/sup>\u00a0mbar(1 \u00d7 10<sup>-9<\/sup>\u00a0to 5 \u00d7 10<sup>-2<\/sup>\u00a0Torr)<\/li>\n\n\n\n<li>Two standard long-life yttrium oxide coated iridium filaments<\/li>\n\n\n\n<li>All-in-One active gauge with built-in display, set-point, analog output and standard integrated RS485 digital interface<\/li>\n\n\n\n<li>Bright digital OLED display with keypad for simple setup, operation and programming<\/li>\n\n\n\n<li>User programmable set point relay<\/li>\n\n\n\n<li>User programmable display units in mbar, Torr or Pa<\/li>\n\n\n\n<li>User selectable Auto-ranging of emission current<\/li>\n\n\n\n<li>Mechanical strength and ruggedness<\/li>\n\n\n\n<li>Choice of various flange options<\/li>\n\n\n\n<li>Easy to exchange sensing element<\/li>\n\n\n\n<li>Compliance &amp; standards: CE, RoHS<\/li>\n\n\n\n<li>Direct drop in replaces Granville-Phillips<sup>\u00ae<\/sup>\u00a0354 Micro-Ion<sup>\u00ae<\/sup>\u00a0Module \u2013 identical control functions including softwarecommands (RS485) (Granville-Phillips<sup>\u00ae<\/sup>\u00a0and Micro-Ion<sup>\u00ae<\/sup>\u00a0are registered trademarks of MKS Instruments, Andover, MA)<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Pressure measurement in semiconductor process and transfer chambers<\/li>\n\n\n\n<li>Industrial coating<\/li>\n\n\n\n<li>General vacuum measurement and control in the low to ultra high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/06\\\/7886-BAG302%20Ordering%20information.jpg?v=1-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:838px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: BAG302 Ordering Information&quot;,&quot;alt&quot;:&quot;BAG302 Ordering Information&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/06\/7886-BAG302%20Ordering%20information.jpg?v=1-0\" alt=\"BAG302 Ordering Information\" style=\"width:838px;height:auto\" title=\"BAG302 Ordering Information\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: BAG302 Ordering Information\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/4050\/download\/BAG302-Datasheet.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">BAG302 Bayard-Alpert Hot Ion Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/bag302\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Medium to Ultra High Vacuum Gauge The INFICON single Bayard-Alpert Hot Ion gauge BAG302 covers a wide measurement range from 1.3 \u00d7 10-9&nbsp;to 6.7\u00d710-2&nbsp;mbar (1 \u00d7 10-9&nbsp;to 5 \u00d7 10-2&nbsp;Torr).&nbsp; The compact All-In-One Hot Ion gauge BAG302 offers an easy to exchange dual filament sensor, a built in OLED display, set-point relay and a log-linear [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4372"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4372"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4372\/revisions"}],"predecessor-version":[{"id":4374,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4372\/revisions\/4374"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4372"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}