{"id":4407,"date":"2024-12-22T16:02:21","date_gmt":"2024-12-22T12:02:21","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4407"},"modified":"2024-12-22T16:02:21","modified_gmt":"2024-12-22T12:02:21","slug":"mag470-cold-cathode-gauges","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/mag470-cold-cathode-gauges\/","title":{"rendered":"MAG470 Cold Cathode Gauges"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Inverted Magnetron Gauges<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 60%\"><div class=\"wp-block-media-text__content\">\n<p>The Inverted Magnetron Vacuum Gauge MAG470 is for all ultra high vacuum applications. The measurement range\u00a0is\u00a0from 5&#215;10<sup>-11<\/sup>\u00a0mbar to 1&#215;10<sup>-2<\/sup>\u00a0mbar.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-292.png\" alt=\"\" class=\"wp-image-4408 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-292.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-292-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>No filament to burn out<\/li>\n\n\n\n<li>Extended version, sensor bakeout up to 250\u00b0C<\/li>\n\n\n\n<li>Excellent ignition properties<\/li>\n\n\n\n<li>Easy to clean<\/li>\n\n\n\n<li>Metal-sealed feedthrough<\/li>\n\n\n\n<li>LED indicator for high voltage on<\/li>\n\n\n\n<li>Logarithmic analog output signal<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Ultra high vacuum pressure monitoring<\/li>\n\n\n\n<li>Base pressure for evaporation and sputtering systems<\/li>\n\n\n\n<li>General vacuum measurement and control in the medium and high vacuum range<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td colspan=\"2\"><strong>MAG470<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>399-360<\/em><\/td><td>MAG470 DN 40 CF-F, FCC<\/td><\/tr><tr><td colspan=\"2\"><strong>MAG470 extended<\/strong><\/td><\/tr><tr><td><strong>Part Number<\/strong><\/td><td>Description<\/td><\/tr><tr><td><em>399-361<\/em><\/td><td>MAG470 DN 40 CF-F, extendet<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/5461\/download\/MAG470-Inverted-Magnetron-Gauge.pdf?v=2&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">MAG470 Inverted Magnetron Gauge<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/mag470\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Inverted Magnetron Gauges The Inverted Magnetron Vacuum Gauge MAG470 is for all ultra high vacuum applications. The measurement range\u00a0is\u00a0from 5&#215;10-11\u00a0mbar to 1&#215;10-2\u00a0mbar. Advantages Typical applications Part Number MAG470 Part Number Description 399-360 MAG470 DN 40 CF-F, FCC MAG470 extended Part Number Description 399-361 MAG470 DN 40 CF-F, extendet Brochures &amp; Data Sheets MAG470 Inverted Magnetron [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4407"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4407"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4407\/revisions"}],"predecessor-version":[{"id":4409,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4407\/revisions\/4409"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4407"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}