{"id":4447,"date":"2024-12-22T15:34:17","date_gmt":"2024-12-22T11:34:17","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4447"},"modified":"2024-12-22T15:34:17","modified_gmt":"2024-12-22T11:34:17","slug":"irc081-vacuum-gauge-controller","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/irc081-vacuum-gauge-controller\/","title":{"rendered":"IRC081 Vacuum Gauge Controller"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Setting the new standard with the Ion Reference Gauge IRG080<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile is-vertically-aligned-top\" style=\"grid-template-columns:auto 59%\"><div class=\"wp-block-media-text__content\">\n<p>The Ion Reference Gauge Controller IRC081 and its User Interface are an operating and display interface to the standardized Ion Reference Gauge IRG080. IRC081 delivers precise and reference total pressure measurement and local control for the IRG080 gauge. Read-out and switch on\/off functionality are available remotely via an USB computer interface.\u00a0<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-301.png\" alt=\"\" class=\"wp-image-4448 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-301.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-301-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>Thanks to the intuitive &#8220;IRC081 User Interface&#8221; software, included, selected settings and measured pressure value can be conveniently graphically displayed. The IRC081 operating unit is offered with different sets of cable length.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Operating and display solution for accurate vacuum pressure measurement<\/li>\n\n\n\n<li>User control on all IRG080 gauge parameters set<\/li>\n\n\n\n<li>Simple manual operation with 5 potentiometers<\/li>\n\n\n\n<li>User Interface connection via USB-B port to PC<\/li>\n\n\n\n<li>PC Software in LabVIEW<sup>TM<\/sup><\/li>\n\n\n\n<li>Data log and parameter log functionality<\/li>\n\n\n\n<li>External port for status and vacuum interlock<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">User Interface<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Your single control window via the IRC081 User Interface<\/strong><\/h3>\n\n\n\n<ul>\n<li>Measurement on\/off control<\/li>\n\n\n\n<li>Emission current control<\/li>\n\n\n\n<li>Full display with pressure value, set voltage values, measured current values, transmission rate<\/li>\n\n\n\n<li>Graph display of the current pressure and current values<\/li>\n\n\n\n<li>Manual or auto set-up of the ion current measurement range<\/li>\n\n\n\n<li>Display for gas type correction and sensitivity (configurable)<\/li>\n\n\n\n<li>Interlock and system status display<\/li>\n\n\n\n<li>Warning and instruction message area<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/www.inficon.com\\\/uploads\\\/media\\\/660x\\\/09\\\/8309-IRC081%20User%20Interface%2001.png?v=2-0&quot;,&quot;figureClassNames&quot;:&quot;aligncenter is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:null,&quot;imgStyles&quot;:&quot;width:960px;height:auto&quot;,&quot;targetWidth&quot;:&quot;none&quot;,&quot;targetHeight&quot;:&quot;none&quot;,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image: IRC081 User Interface single control window&quot;,&quot;alt&quot;:&quot;IRC081 User Interface single control window&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter is-resized wp-lightbox-container\"><img decoding=\"async\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/www.inficon.com\/uploads\/media\/660x\/09\/8309-IRC081%20User%20Interface%2001.png?v=2-0\" alt=\"IRC081 User Interface single control window\" style=\"width:960px;height:auto\" title=\"IRC081 User Interface single control window\"\/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image: IRC081 User Interface single control window\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Part Number<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>399-880<\/td><td>IRC081 Ion Reference Gauge Controller, USB 2.0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/8680\/download\/IRC081-Ion-Reference-Gauge-Controller.pdf?v=4&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">IRC081 Ion Reference Gauge Controller<\/a><\/strong> Data Sheet<\/p>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/8216\/download\/IRG080-Brochure-.pdf?v=3&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Ion Reference Gauge IRG080<\/a><\/strong> Brochure<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/vacuum-gauge-and-controller\/irc081\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4136\"><strong><em>Vacuum Gauges &amp; Controllers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Setting the new standard with the Ion Reference Gauge IRG080 The Ion Reference Gauge Controller IRC081 and its User Interface are an operating and display interface to the standardized Ion Reference Gauge IRG080. IRC081 delivers precise and reference total pressure measurement and local control for the IRG080 gauge. Read-out and switch on\/off functionality are available [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4447"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4447"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4447\/revisions"}],"predecessor-version":[{"id":4449,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4447\/revisions\/4449"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4447"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}