{"id":4482,"date":"2024-12-22T17:41:43","date_gmt":"2024-12-22T13:41:43","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4482"},"modified":"2024-12-22T17:41:45","modified_gmt":"2024-12-22T13:41:45","slug":"quantus-hp100-optical-gas-analyzer","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/quantus-hp100-optical-gas-analyzer\/","title":{"rendered":"Quantus\u00ae HP100 Optical Gas Analyzer"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Real-time Leak Detection, Endpoint Detection and Process Monitoring<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 65%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-305.png\" alt=\"\" class=\"wp-image-4483 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-305.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-305-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<p>INFICON Quantus HP100 gas analyzer is based on Self-Plasma Optical Emission Spectroscopy (SPOES) technology and is designed to provide real-time leak detection, endpoint detection and process monitoring during semiconductor manufacturing. Quantus HP100 has excellent sensitivity, a compact form factor and offers wide operational pressure range without costly pumps, making it well suited for process monitoring and protection in most semiconductor tools.<\/p>\n\n\n\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Quantus HP100 product video\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/vxax-fn9t-0?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul>\n<li>Operating range of 1 Torr \u2013 450 Torr for Argon and 1 Torr \u2013 120 Torr for Nitrogen (Varies for other gas species)<\/li>\n\n\n\n<li>Low detection limits &lt;1 ppm<\/li>\n\n\n\n<li>Easy installation using a standard KF25 connection<\/li>\n\n\n\n<li>Fast sampling (20 Hz maximum)<\/li>\n\n\n\n<li>Small footprint (H x W x L): 6.4 x 6.0 x 8.3 in. [162 x 153 x 210 mm]<\/li>\n\n\n\n<li>Low maintenance, no pumps or consumables required<\/li>\n\n\n\n<li>Convenient field-replaceable plasma cell<\/li>\n\n\n\n<li>Worldwide expert support for your particular process needs<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Specifications<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>Operating pressure&nbsp;<\/td><td>1 Torr &#8211; 450 Torr (application dependent)<\/td><\/tr><tr><td>Spectrometer performance<\/td><td>200 to 850 nanometer wavelengths (UV-VIS) 16-bit full-scale resolution, 3648 pixels<\/td><\/tr><tr><td>Detection limit<\/td><td>&lt; 1 ppm (application dependent)<\/td><\/tr><tr><td>Exposure time<\/td><td>Minimum of 1 ms<\/td><\/tr><tr><td>Vacuum fitting<\/td><td>KF25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p><strong><a href=\"https:\/\/www.inficon.com\/media\/8164\/download\/Quantus-HP100-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Quantus HP100 Gas Analyzer<\/a><\/strong> Brochure<\/p>\n\n\n\n<p><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/gas-analysis\/quantus-hp100\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3493\"><strong><em>Optical Gas Analyzers Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Real-time Leak Detection, Endpoint Detection and Process Monitoring INFICON Quantus HP100 gas analyzer is based on Self-Plasma Optical Emission Spectroscopy (SPOES) technology and is designed to provide real-time leak detection, endpoint detection and process monitoring during semiconductor manufacturing. Quantus HP100 has excellent sensitivity, a compact form factor and offers wide operational pressure range without costly [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4482"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4482"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4482\/revisions"}],"predecessor-version":[{"id":4492,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4482\/revisions\/4492"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}