{"id":4506,"date":"2024-12-22T19:47:55","date_gmt":"2024-12-22T15:47:55","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4506"},"modified":"2024-12-22T19:47:56","modified_gmt":"2024-12-22T15:47:56","slug":"transpector-apx-multi-pressure-mass-spectrometer","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/transpector-apx-multi-pressure-mass-spectrometer\/","title":{"rendered":"Transpector APX Multi-Pressure Mass Spectrometer"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Advanced Process Expert for Multi-Pressure ALD\/CVD and Etch<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 72%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-309.png\" alt=\"\" class=\"wp-image-4507 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-309.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-309-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Minimize Scrap and Maximize Yield in Real Time<\/h2>\n\n\n\n<p>INFICON Transpector APX remains the market leading Residual Gas Analyzer (RGA) for semiconductor and display process monitoring. INFICON knows semiconductor and display customers have unique needs, and the latest revision of the Transpector APX allows for more flexibility to meet specific application requirements, while maintaining industry leading measurement speed and sensitivity. Transpector APX is the ideal RGA process monitor for semiconductor processes such as ALD, CVD, PVD, and Etch.<\/p>\n\n\n\n<p>The next generation Transpector APX Multi-Pressure inlet system is designed to survive process chemistries prone to particle or coating generation like ALD or PECVD. This allows for continuous monitoring to capture data points at all critical process steps. In addition the HexBlock inlet is available with INFICON proprietary coating for resistance to corrosive gases, essential for chamber clean endpoint monitoring applications.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure data-wp-context=\"{&quot;uploadedSrc&quot;:&quot;https:\\\/\\\/iss-lab.com\\\/wp-content\\\/uploads\\\/2024\\\/12\\\/image-310.png&quot;,&quot;figureClassNames&quot;:&quot;aligncenter size-large is-resized&quot;,&quot;figureStyles&quot;:null,&quot;imgClassNames&quot;:&quot;wp-image-4508&quot;,&quot;imgStyles&quot;:&quot;width:902px;height:auto&quot;,&quot;targetWidth&quot;:1590,&quot;targetHeight&quot;:895,&quot;scaleAttr&quot;:false,&quot;ariaLabel&quot;:&quot;Enlarge image&quot;,&quot;alt&quot;:&quot;&quot;}\" data-wp-interactive=\"core\/image\" class=\"aligncenter size-large is-resized wp-lightbox-container\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" data-wp-init=\"callbacks.setButtonStyles\" data-wp-on--click=\"actions.showLightbox\" data-wp-on--load=\"callbacks.setButtonStyles\" data-wp-on-window--resize=\"callbacks.setButtonStyles\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-1024x576.png\" alt=\"\" class=\"wp-image-4508\" style=\"width:902px;height:auto\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-1024x576.png 1024w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-300x169.png 300w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-768x432.png 768w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-1536x865.png 1536w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310-640x360.png 640w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-310.png 1590w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><button\n\t\t\tclass=\"lightbox-trigger\"\n\t\t\ttype=\"button\"\n\t\t\taria-haspopup=\"dialog\"\n\t\t\taria-label=\"Enlarge image\"\n\t\t\tdata-wp-init=\"callbacks.initTriggerButton\"\n\t\t\tdata-wp-on--click=\"actions.showLightbox\"\n\t\t\tdata-wp-style--right=\"context.imageButtonRight\"\n\t\t\tdata-wp-style--top=\"context.imageButtonTop\"\n\t\t>\n\t\t\t<svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"12\" height=\"12\" fill=\"none\" viewBox=\"0 0 12 12\">\n\t\t\t\t<path fill=\"#fff\" d=\"M2 0a2 2 0 0 0-2 2v2h1.5V2a.5.5 0 0 1 .5-.5h2V0H2Zm2 10.5H2a.5.5 0 0 1-.5-.5V8H0v2a2 2 0 0 0 2 2h2v-1.5ZM8 12v-1.5h2a.5.5 0 0 0 .5-.5V8H12v2a2 2 0 0 1-2 2H8Zm2-12a2 2 0 0 1 2 2v2h-1.5V2a.5.5 0 0 0-.5-.5H8V0h2Z\" \/>\n\t\t\t<\/svg>\n\t\t<\/button><\/figure><\/div>\n\n\n<h2 class=\"wp-block-heading\">Advantages<\/h2>\n\n\n\n<ul>\n<li>Application specific platform design for longest lifetime on your ALD or CVD process for the best wafer and panel protection and process optimization<\/li>\n\n\n\n<li>ALD ready with measurement speeds of over 550 data points per second<\/li>\n\n\n\n<li>Reduced fab footprint by 30% and easier installation due ne high performance pumping system<\/li>\n\n\n\n<li>Configurable HexBlock\u2122 with INFICON proprietary coating with up to three pressure inlets that can withstand harsh corrosive chemistry<\/li>\n\n\n\n<li>Automated calibration ensures long-term data reliability and accuracy for sensor to sensor and tool to tool chamber matching<\/li>\n\n\n\n<li>Transpector APX becomes a powerful process monitoring and diagnostics tool when integrated with FabGuard<sup>\u00ae\u00a0<\/sup>software and supported by INFICON world-class application experts<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-embed aligncenter is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Transpector\u00ae APX\" width=\"750\" height=\"422\" src=\"https:\/\/www.youtube.com\/embed\/wNuoSBTbFmI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Specifications<\/h2>\n\n\n\n<p class=\"has-medium-font-size\"><strong>100 AMU<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Total Pressure Range<\/strong><\/td><td>5E-7 \u2013 1E-3 Torr6.6E-7 \u2013 1.3E-3 mbar<\/td><\/tr><tr><td><strong>Detection Limit<\/strong><\/td><td>&lt;10 ppb<\/td><\/tr><tr><td><strong>Process Pressure Range<\/strong><\/td><td>1E-8 Torr \u2013 1.2 atm1.3E-8 mbar \u2013 1.2 atm<\/td><\/tr><tr><td><strong>Sensitivity (Low Emission)<\/strong><\/td><td>&gt;4.0E-6 amps\/Torr&gt;3E-6 amps\/mbar<\/td><\/tr><tr><td><strong>Sensitivity (High Emission)<\/strong><\/td><td>&gt;2.0E-5 amps\/Torr&gt;1.5E-5 amps\/mbar<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-medium-font-size\"><strong>200 AMU<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Total Pressure Range<\/strong><\/td><td>5E-7 \u2013 1E-3 Torr6.6E-7 \u2013 1.3E-3 mbar<\/td><\/tr><tr><td><strong>Detection Limit<\/strong><\/td><td>&lt;25 ppb<\/td><\/tr><tr><td><strong>Process Pressure Range<\/strong><\/td><td>1E-8 Torr \u2013 1.2 atm1.3E-8 mbar \u2013 1.2 atm<\/td><\/tr><tr><td><strong>Sensitivity (Low Emission)<\/strong><\/td><td>&gt;2.0E-6 amps\/Torr&gt;1.5E-6 amps\/mbar<\/td><\/tr><tr><td><strong>Sensitivity (High Emission)<\/strong><\/td><td>&gt;1.0E-5 amps\/Torr&gt;7.6E-6 amps\/mbar<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"has-medium-font-size\"><strong>300 AMU<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Total Pressure Range<\/strong><\/td><td>5E-7 \u2013 1E-3 Torr6.6E-7 \u2013 1.3E-3 mbar<\/td><\/tr><tr><td><strong>Detection Limit<\/strong><\/td><td>&lt;50 ppb<\/td><\/tr><tr><td><strong>Process Pressure Range<\/strong><\/td><td>1E-8 Torr \u2013 1.2 atm1.3E-8 mbar \u2013 1.2 atm<\/td><\/tr><tr><td><strong>Sensitivity (Low Emission)<\/strong><\/td><td>&gt;1.0E-6 amps\/Torr&gt;7.6E-7 amps\/mbar<\/td><\/tr><tr><td><strong>Sensitivity (High Emission)<\/strong><\/td><td>&gt;5.0E-6 amps\/Torr&gt;3.8E-6 amps\/mbar<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Consumables<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td><strong>Part Number<\/strong><\/td><td><strong>Description<\/strong><\/td><\/tr><tr><td>969-800-G1S<\/td><td>APX CIS Tungsten Filament Kit GOLD<\/td><\/tr><tr><td>969-800-G2S<\/td><td>APX CIS Coated Filament Kit GOLD<\/td><\/tr><tr><td>969-801-G1S<\/td><td>APX CIS Tungsten Ion Source Kit GOLD<\/td><\/tr><tr><td>969-801-G2S<\/td><td>APX CIS Tungsten Ion Source Kit with Anode Liner GOLD<\/td><\/tr><tr><td>969-801-G3S<\/td><td>APX CIS Coated Ion Source Kit GOLD<\/td><\/tr><tr><td>969-801-G4S<\/td><td>APX CIS Coated Ion Source Kit with Anode Liner GOLD<\/td><\/tr><tr><td>961-707-G1<\/td><td>Electron Multiplier Replacement Kit<\/td><\/tr><tr><td>923-418-G2<\/td><td>Replacement diaphragm kit for 2-stage pump<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p class=\"has-medium-font-size\"><strong><a href=\"https:\/\/www.inficon.com\/media\/7804\/download\/Transpector-APX-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Transpector\u00ae APX Residual Gas Analyzer<\/a><\/strong> Brochure<\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/gas-analysis\/transpector-apx-multi-pressure\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=3478\"><em><strong>Mass Spectrometers<\/strong> <strong>Page<\/strong><\/em><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/leak-detection\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Leak Detection Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/products-technologies\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Products &amp; Technologies Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Advanced Process Expert for Multi-Pressure ALD\/CVD and Etch Minimize Scrap and Maximize Yield in Real Time INFICON Transpector APX remains the market leading Residual Gas Analyzer (RGA) for semiconductor and display process monitoring. INFICON knows semiconductor and display customers have unique needs, and the latest revision of the Transpector APX allows for more flexibility to [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4506"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4506"}],"version-history":[{"count":2,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4506\/revisions"}],"predecessor-version":[{"id":4510,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4506\/revisions\/4510"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}