{"id":4738,"date":"2024-12-23T19:53:14","date_gmt":"2024-12-23T15:53:14","guid":{"rendered":"https:\/\/iss-lab.com\/?page_id=4738"},"modified":"2024-12-23T19:53:15","modified_gmt":"2024-12-23T15:53:15","slug":"research-crystals-1-inch-25-4mm","status":"publish","type":"page","link":"https:\/\/iss-lab.com\/index.php\/research-crystals-1-inch-25-4mm\/","title":{"rendered":"Research Crystals 1 inch (25.4mm)"},"content":{"rendered":"\n<p class=\"has-medium-font-size\"><strong>Maximum stability in demanding applications<\/strong><\/p>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\" style=\"grid-template-columns:auto 67%\"><div class=\"wp-block-media-text__content\">\n<p><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"500\" height=\"335\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-383.png\" alt=\"\" class=\"wp-image-4739 size-full\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-383.png 500w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-383-300x201.png 300w\" sizes=\"(max-width: 500px) 100vw, 500px\" \/><\/figure><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><a href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"QMC Free Samples noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"287\" src=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-382-1024x287.png\" alt=\"\" class=\"wp-image-4735\" style=\"width:892px;height:auto\" srcset=\"https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-382-1024x287.png 1024w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-382-300x84.png 300w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-382-768x215.png 768w, https:\/\/iss-lab.com\/wp-content\/uploads\/2024\/12\/image-382.png 1146w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n<p>The standard AT-cut, 1 in. (25.4 mm) diameter crystal, pioneered by INFICON, is used primarily in research applications with the INFICON RQCM (Research Quartz Crystal Microbalance). These research crystals are designed for use with INFICON rugged, easy to use crystal holders and are used for in-situ monitoring of deposited films or liquids.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Geometry<\/strong><\/h2>\n\n\n\n<p>AT-cut quartz has superior mechanical and piezoelectric properties. The 1 in. (25.4 mm) diameter allows optimal distance between the active area of the crystal and the mounting o-ring. This improves the overall stability of the crystal by reducing the frequency changes due to mounting stress.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Finish<\/strong><\/h2>\n\n\n\n<p>INFICON 1 in. (25.4 mm) research crystals are available with either an unpolished or polished finish. Polished crystals allow for a good correlation between theory and measurement during liquid immersion experiments.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Electrode Material<\/strong><\/h2>\n\n\n\n<p>INFICON 1 in. (25.4 mm) research crystals are available in a variety of electrode materials including Gold, Platinum, and Titanium. Crystals with custom electrode materials are available on request. INFICON also offers Gold electrode crystals with an additional SiO<sub>2<\/sub>&nbsp;outer layer to create a hydrophilic surface needed for some biological applications.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Temperature<\/strong><\/h2>\n\n\n\n<p>Even though AT-cut crystals are designed to minimize the change in frequency due to temperature, the effect of temperature can be significant when attempting to resolve small mass (frequency) changes over long periods of time. INFICON offers AT-cut crystals optimized for two operating temperatures, 90\u00baC and 25\u00baC. These crystals have very good frequency stability when operating close to their specified temperature.<br \/><br \/>Contact us today to request a quote for custom crystals to accommodate your special requirements.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Features<\/h2>\n\n\n\n<ul>\n<li>Accurate<\/li>\n\n\n\n<li>Reliable<\/li>\n\n\n\n<li>Stable<\/li>\n\n\n\n<li>Wide variety of electrode materials available<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Typical applications<\/h2>\n\n\n\n<ul>\n<li>Metal plating<\/li>\n\n\n\n<li>Gas-phase mass detection<\/li>\n\n\n\n<li>Electro-chemistry<\/li>\n\n\n\n<li>Micro-rheology<\/li>\n\n\n\n<li>Protein adsorption\/desorption<\/li>\n\n\n\n<li>Biofilm formation<\/li>\n<\/ul>\n\n\n\n<p class=\"has-medium-font-size\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Brochures &amp; Data Sheets<\/h2>\n\n\n\n<p class=\"has-medium-font-size\"><strong><a href=\"https:\/\/www.inficon.com\/media\/3586\/download\/Research-Crystal-Brochure.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">Research Crystals<\/a><\/strong> Brochure<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong><a href=\"https:\/\/www.inficon.com\/media\/4706\/download\/What-is-a-QCM-Sensor?.pdf?v=1&amp;inline=true&amp;language=en\" target=\"_blank\" rel=\"noreferrer noopener\">What is a QCM Sensor?<\/a><\/strong><\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-left is-layout-flex wp-container-core-buttons-is-layout-1 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/www.inficon.com\/en\/products\/thin-film-technology\/research-crystals-1-inch-254mm\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>More Information<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4646\"><em><strong>Thin Film Sensors &amp; Feedthroughs<\/strong> <strong>Page<\/strong><\/em><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/?page_id=4573\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Thin Film Technology Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/products-technologies\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Products &amp; Technologies Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-25 is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/\"><strong><em>Home Page<\/em><\/strong><\/a><\/div>\n\n\n\n<div class=\"wp-block-button is-style-outline\"><a class=\"wp-block-button__link wp-element-button\" href=\"https:\/\/iss-lab.com\/index.php\/contact-us\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><em>Contact us<\/em><\/strong><\/a><\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Maximum stability in demanding applications The standard AT-cut, 1 in. (25.4 mm) diameter crystal, pioneered by INFICON, is used primarily in research applications with the INFICON RQCM (Research Quartz Crystal Microbalance). These research crystals are designed for use with INFICON rugged, easy to use crystal holders and are used for in-situ monitoring of deposited films [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_mi_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"_links":{"self":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4738"}],"collection":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/comments?post=4738"}],"version-history":[{"count":1,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4738\/revisions"}],"predecessor-version":[{"id":4740,"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/pages\/4738\/revisions\/4740"}],"wp:attachment":[{"href":"https:\/\/iss-lab.com\/index.php\/wp-json\/wp\/v2\/media?parent=4738"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}